Download Inhoudsopgave Inhoud Print deze pagina

Technical Details - WANDERS Black Diamond Handleiding En Installatievoorschriften

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Technical details

Door latch
Nominal capacity*
Flue collar
Maximum lumber supply
* the nominal heat is obtained with a chimney draft of 0.12 mBar
Fuel: wood logs (30 x 10 cm)
Maximum supply
Primary airvalve
Secundary air outlet
Fuel burning period
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When the door is closed and fueled with wood
Flue gas quantity
Flue gas temperature
Pre pressure
E ciency
CO at 13% O
2
Particulate matter
Certi cate institute
Test standard
Test report number
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be taken
for the volume of the spaces to be heated:
If heating circumstances are favourable:
In less favourable circumstances:
In unfavourable circumstances:
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is
more than 8 hours.
28
Black Diamond
Black Diamond Compact
I & II
8
150
3
Black Diamond
Black Diamond Compact
8,4
290
0,12
78,9
0,07
26
1625
EN13240
RRF - 400 169
RRF - 4011 2705
calculate according to DIN 4701
135 (Black Diamond) 130 (Compact) m
95 (Black Diamond) 90 (Compact) m
I & II
Ba
7
kW
150
mm
3
kg
3 pieces
maximum
maximum
about 1 hour
8,4
g/s
290
C
0
0,12
mBar
79,0
%
0,05
%
25
mg/m
1625
EN13240
3
3
3

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Black diamond compact

Inhoudsopgave