6.APPENDIX
5.1 Kabel specificaties
1. één fase
Nameplate
maximum
Phase line
current
No more
2×1.5mm
than 10A
10~16A
2×2.5mm
16 ~25A
2×4mm
25 ~32A
2×6mm
32 ~40A
2×10mm
40 ~63A
2×16mm
63~75A
2×25mm
75~101A
101~123A
2×25mm
123~148A
2×35mm
148~186A
2×50mm
186~224A
2×70mm
2. Drie fasen
Nameplate
maximum
Phase line
current
No more
3×1.5mm
than 10A
10~16A
3×2.5mm
16 ~25A
3×4mm
25 ~32A
3×6mm
32 ~40A
40 ~63A
3×10mm
3 × 16mm
63~75A
3 × 25mm
75~101A
101~123A
3×25mm
123~148A
3×35mm
148~186A
3×50mm
186~224A
3×70mm
.
MCB
Earth line
2
2
1.5mm
20A
2
2
2.5mm
32A
2
40A
2
4mm
2
40A
6mm
2
2
63A
10mm
2
2
80A
16mm
2
2
100A 30mA less than 0.1 sec
25 mm
2
2
125A 30mA less than 0.1 sec
25 mm
2
2
160A 30mA less than 0.1 sec
35mm
2
2
50mm
225A 30mA less than 0.1 sec
2
70mm
250A 30mA less than 0.1 sec
2
2
95mm
280A 30mA less than 0.1 sec
2
Earth line
MCB
2
2
1.5mm
20A
2
2
2.5mm
32A
2
2
4mm
40A
2
6mm
40A
2
2
10mm
63A
2
2
16mm
80A
2
2
25 mm
100A 30mA less than 0.1 sec
2
2
25 mm
125A 30mA less than 0.1 sec
2
2
35mm
160A 30mA less than 0.1 sec
2
2
50mm
225A 30mA less than 0.1 sec
2
70mm
250A 30mA less than 0.1 sec
2
2
95mm
280A 30mA less than 0.1 sec
2
Creepage protector
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
Creepage protector
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
30mA less than 0.1 sec
25
Signal line
n × 0.5mm 2
Signal line
n × 0.5mm 2