eNet
eNet tastafdekking met radiografische ontvanger
Manual commissioning
Allow extension unit operation On, Off
Settings, channel
Parameters
Manual commissioning
Operating mode
Local Operation
Manual switch-off of the run-
on time
Switch-on brightness
32582713
J0082582713
On, Off
Basic setting: On
Basic setting: On
Setting options, Basic set­
ting
On, Off
Basic setting: On
Normal operation
Continuous on
Continuous off
Basic setting: Normal Operati-
on
On, Off
Basic setting: On
On, Off
Basic setting: Off
1...100 %
Basic setting: 100 %
5/10
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Prevents operation via wired
extensions.
Explanations
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Normal operation
The output can be operated
with radio transmitters, with
the button and with a connec-
ted extension.
Continuous on
The output switches to conti-
nuously "On". All operations of
radio transmitters, of the but-
ton and of connected extensi-
ons are ignored.
Continuous off
The output switches to conti-
nuously "Off". All operations of
radio transmitters, of the but-
ton and of connected extensi-
ons are ignored.
Blocks the output for operation
using the button.
Allows manual switch-off of a
running run-on time. If the
parameter is switched off, then
a switch-off command will also
switch the actuator on. This
parameter is directly connec-
ted to the "Run-on time" para-
meter.
During brief operation, the out-
put switches on at the set
switch-on brightness.
Note: If the value is above the
set maximum brightness or
below the minimum
brightness, then the system
will switch to the appropriate
limit value.