41
Foutnummer
230-04DD
230-04DE
230-04E0
230-04E2
2520
Beschrijving
Error message
Ingang voor SBC.GLOBAL niet correct geconfigureerd
Cause of error
For the use of the SBC.GLOBAL input terminal of the PAE
module, the corresponding machine function was either not
configured in the IO configuration (IOC file) or it was configu-
red incorrectly.
- No PAE module was configured.
- A PAE module with an outdated version of the HDD file was
configured.
- More than one PAE module was configured.
- SBC.GLOBAL was configured on the wrong module.
Error correction
- Check the IO configuration
- Inform your service agency
Error message
Ingang voor SBC.GLOBAL mag niet worden geconfigureerd
Cause of error
Do not configure the machine function SBC.GLOBAL in the
IO configuration (IOC file) of systems with integrated functio-
nal safety.
Error correction
- Check the IO configuration
- Inform your service agency
Error message
Eindschak./veiligheidszone niet correct geprogrammeerd
voor as %2
Cause of error
Protection zones for modulo axes should not be used with
this version of the control software.
Error correction
- Remove protection zone for modulo axis
- Do not configure the axis as a modulo axis
Error message
Startpositie van de as (%2) niet toegestaan bij regelsprong
Cause of error
De startpositie van de as ligt buiten het toegestane verplaat-
singsbereik.
Error correction
- Configuratie van de software-eindschakelaars controleren
- Startpunten van de assen in het NC-programma controle-
ren
NC-foutmeldingen | Lijst met NC-foutmeldingen