c) Display code representative function:
Heating element (40°C~99°C) –95°C by default
HP
Drinking temperature (40°C~9S°C) –93°C by default
dP
return difference temperature (1°C~30°C) –2°C by default
Hy
timer on–Hour(0~23)
timer on–Minute (0~69)
o
timer off–Hour (0~23)
HoF
timer off–Minute (0~59)
oF
Current time–Hour
Ht
Current time–Minute
t
Current time–Second
5t
remark:
• the heating temperature, drinking temperature and return difference temperature have been set up well
in factory, user can not change the default temperature.
• the set time of the "timer on" means the start working time of the machine.
• the set time of the "timer off" means the stop working time of the machine.
• Please set up the "Current time" according to the local standard time.
7. the presets in factory:
a) temperature: the green (drinkable) indicator light on when it reach 93°C (heat up to 100°C right
along), the outlet water temperature is 93~100°C. the outlet water temperature is the same as the
displayed temperature.
b) elevation: for adapting different regional pressure, user can contact the local sales agent for help.
By using the switch "Plateau area heating mode" in the circuit board in the machine,
user need not to have further adjustment generally.
8. timer:
a) Machine remains oFF, first set up the "Current time", the display code can contrast with the sheet
above, and please set the time according to the local standard time.
Setting procedure: 1. press the "Set" button to switch "Hour"/"Minute"/"Second" code;
b) Setting "timer on", you can contrast with the sheet above when operating.
Procedure:
c) Setting "timer off", you can contrast with the sheet above when operating.
Procedure:
d) after finishing these three procedure before, press "Set" button to switch to oFF status,
long press the "Switch" button for 2 seconds, the machine start working,
then press the "timing" button, the timing indicator light on, means the timing function is effective.
688120 nl-en ma 2016
2. press "Plus" or "Minus" button to set your needed time, then exit to save the data;
3. repeat the procedure to set up other two data.
1. press "Set" button to switch between "Hour"/"Minute";
2. press "Plus" or "Minus" button to set your needed time,
then exit to save the data; repeat the procedure to set up another data.
1. press "Set" button to switch between "Hour"/"Minute";
2. press "Plus" or "Minus" button to set your needed time,
then exit to save the data; repeat the procedure to set up another data.
15