Beschikbare talen

mode is displayed for approx. 3 s before the
button goes out.
If the setting is not confirmed by holding down
the button, the device will revert to its previous
dimming mode after 2 minutes.
If the operating mode selected is not suitable
for the connected load, the dimming channel
will reset to „factory setting" automatically.
Lighting
Dimming mode
button (2)
yellow
Energy-saving lamps
purple
Capacitive load (CFL)
blue
Inductive load
red
LED load
green
taught-in load (CFL + LED)
white
automatic load setting (factory
setting)
1) The load for the selected dimming mode is only taught
in for approx. 30 s. This can lead to temporary impair-
ment of the lighting.
Table 2
Displaying dimming mode
„ Short press on dimming mode button (2).
The coloured lighting of the button will display
the current operating mode for approx. 3 s
(Table 2).
Teach in the load of an operating unit via the
button
When teaching in the connected load, the dimming
performance for compact fluorescent lamps and
LED lamps is optimised.
The device is ready for operation. The dimming
button of an operating unit has been programmed
with the taught-in output.
„ Press the dimming button 5 times briefly, then
keep the button pressed until the load switches
off.
The short press is independent of the config-
ured operating performance on the operating
unit ( 5 x On, 5 x Off or 5 x On/Off).
„ Press button once briefly.
The teach-in procedure lasts approx. 30 s. To
optimise the dimming performance, a dimming
operation is performed. After teaching in, the
connected load lights up at maximum bright-
ness and flashes once. The teach-in process is
complete.
Depending on the connected load, the minimum
brightness may change due to the teach-in
process.
Resetting taught-in loads in the device
The device can be reset to automatic load detec-
tion, e.g. after replacing illuminants.
Automatic load detection is particularly suitable
for loads that can be dimmed clearly in the
phase cut-on or phase cut-off („conventional
loads").
The device is ready for operation. The dimming
button of an operating unit has been programmed
with the taught-in output.
„ Press the dimming button 5 times briefly, then
keep the button pressed until the load switches
off.
The short press is independent of the config-
ured operating performance on the operating
unit ( 5 x On, 5 x Off or 5 x On/Off).
If the dimming button is no longer pressed with-
in the next 10 seconds, the learned dimming
principle is retained.
„ Press button 2 times briefly.
The load flashes twice. The automatic load
detection is enabled again.
All manuals and user guides at all-guides.com
Appendix
Technical data
Supply voltage
via mains
Mains frequency
Supply voltage KNX/EIB
Current consumption KNX/EIB
Consumption without load
Surge voltage
1)
Upstream protection: circuit breaker
Degree of protection of housing
Degree of protection of housing
under front panel
1)
IK (impact protection)
Overvoltage class
Dimension
Connection capacity
Operating temperature
Storage temperature
Communication media KNX
Configuration mode
Variant 300 W
Energy dissipation
230 V incandescent lamps, halogen lamps 300 W
12 V / 24 V halogen lamps
with conventional transformer
12 V / 24 V halogen lamps
with electronic transformer
Dimmable energy-saving lamps (CFL)/
Dimmable LED lamps
Variant 600 W
Energy dissipation
230 V incandescent lamps, halogen lamps 600 W
12 V / 24 V halogen lamps
with conventional transformer
12 V / 24 V halogen lamps
with electronic transformer
Dimmable energy-saving lamps (CFL)/
Dimmable LED lamps
Conventional or electronic transformers should
not be operated with less than 75% of their
nominal load.
Troubleshooting
Manual operation not possible
230V~ +10/-15%
Cause 1: Switch (1) not moved to
240V~ +6/-6%
Move switch to
50/60 Hz
Cause 2: Manual operation is not enabled (Sys-
21-32V
SELV
temlink).
s
2.3 mA
Enable manual operation via application soft-
ware.
350 mW
4 kV
Connected loads do not light up
10 A
Cause1 : Electronic short-circuit and overload
IP 20
protection has triggered, control LED (8) lights up/
flashes.
IP30
Reduce connected load, check wiring and
repair if necessary.
04
Cause 2 : Overheating protection has triggered,
III
control LED (9) lights up.
4 modules, 4 x 17.5 mm
Reduce connected load, provide sufficient cool-
0.75 mm²...2.5 mm²
ing, increase distance to adjacent devices.
-5 ...+ 45°C
Bus operation is not possible
- 20 ...+ 70°C
Cause 1 : Bus voltage is not present.
TP 1
Check bus connection terminals for correct
S-Mode, easy link
polarity.
controller (8031 10 1..)
Check bus voltage by briefly pressing the
programming button (6), red LED flashes if bus
voltage is present. If mains voltage is availa-
4 W
ble without bus voltage, the red LED is lit up
permanently.
Cause 2 : Manual operation is active. Switch (1) is
300 VA
in position
Move switch (1) to position auto.
300 W
Warranty
60 W
We reserve the right to make technical and formal
changes to the product in the interest of technical
progress.
7.5 W
Our products are under guarantee within the scope
of the statutory provisions.
If you have a warranty claim, please contact the
600 VA
point of sale or ship the device postage free with a
description of the fault to the appropriate regional
600 W
representative.
120 W
(Applicable in the European Union and other European
countries with separate collection systems).
This marking shown on the product or its literature
indicates that it hould not be disposed with other
household wasted at the end of its working life. To prevent
possible harm to the environment or human health from
uncontrolled waste disposal, please separate this from
other types of wastes and recycle it responsibly to
promote the sustainable reuse of material resources.
Household users should contact either the retailer where
they purchased this product, or their local government
office, for details of where and how they can take this item
for environmentally safe recycling.
Business users should contact their supplier and check
the terms and conditions of the purchase contract. This
product should not be mixed with other commercial
wastes of disposal.
Usable in all Europe
.
.
.
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment).
å
and in Switzerland
6LE000487C - 12/2016

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

8031 10 1 series

Inhoudsopgave