refill pressure again. In this manual refill cycle, the pump
will be switched on and off and the refill valve will stay
open.
6.8
Various remarks
When the unit is connected to mains power, the
•
display is shown automatically after touching the
screen.
The display switches off automatically after not
•
being touched for 5 minutes.
The degassing or refilling process is stopped by a
•
stop procedure, making sure that the unit stops in a
safe situation (overpressure). This stopping
procedure may take some time (max. 20 seconds).
When a pump has not run for 96 hours, an
•
automatic pump test (15 seconds) will run at the
next Auto degass time.