4 Commissioning
Type
Type of cooling
15
Air
25
Air
24
Air
26
Air
36
Air
240 D
Liquid
401 D
Liquid
401
Liquid
501 D
Liquid
501
Liquid
Tab. 2
Product-specific torch data (EN 60974-7)
Cooling data
Flow temp.
Max. 40 °C
Flow
Min. 1.5 l/min
Flow pressure
Min. 2.5 bar/max. 3.5 bar
Tab. 3
Cooling data/cable assembly
3.2
Illustrations used
All illustrations can be found at the beginning of the operating instructions.
4
Commissioning
DANGER
Risk of injury due to unexpected start
Turn off the entire system prior to assembling, disassembling or servicing parts of the device.
• Close all supply lines.
• Disconnect the electrical power supply.
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The product warranty will be rendered invalid if
work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
WARNING
Electric shock due to touching live components
Touching live equipment parts may result in potentially fatal electric shocks.
• Only hold and move the welding torch using the intended handle piece.
WARNING
Electric shock due to damaged or improperly installed components
Damaged or improperly installed components may result in potentially fatal electric shocks. Components include: Welding torch, cable assembly, spare parts,
wear parts.
• Inspect all components prior to each use and check that all connections are duly installed and undamaged.
• Clean soiled components immediately.
• Replace damaged components immediately.
• Damaged, deformed or worn components must only be replaced by an electrician who has been trained by ABICOR BINZEL.
Perform the following activities prior to every use:
1 Inspect, clean and, if necessary, replace the welding torch.
2 Inspect, clean and, if necessary, replace the spare and wear parts.
3 Inspect, clean and, if necessary, replace the cable assembly.
EN - 34
MB EVO PRO
Load
CO
M21
CO
2
2
A
A
A
-
-
180
180
150
150
230
200
230
250
220
250
270
240
270
320
290
320
325
300
300
450
400
400
475
425
450
550
500
500
575
525
550
MB EVO
Duty cycle
Load
M21
A
%
180
35
150
60
200
60
220
60
240
60
290
60
270
100
350
100
400
100
450
100
500
100
Cable assembly
Standard length L
Coolant connection
Cooling device output
Control lead
MB EVO PRO/MB EVO
Wire ø
Gas flow rate
mm
L/min
0.6–1.0
10–18
0.8–1.2
10–18
0.8–1.2
10–18
0.8–1.2
10–18
0.8–1.2
10–20
0.8–1.2
10–20
0.8–1.6
10–20
0.8–1.6
10–20
1.0–1.6
10–20
1.0–1.6
10–20
3.00 m, 4.00 m, 5.00 m
Plug-in nipple with nom. diam. 5
Min. 800 W
2 lead