Download Print deze pagina

Keba KeContact P20 Gebruikershandboek pagina 28

Verberg thumbnails Zie ook voor KeContact P20:

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 96
Fault in the power unit (is displayed in the colors red/blue)
"blue / blue / red / red"
"blue / red / blue / red"
Resetting an fault:
If an interruption occurs during the plugging-in or charging procedure, the charging station will attempt to au-
tomatically restart the procedure (max. 5 times).
If the charging procedure is not able to be started, this must be confirmed by properly ending the charging
procedure (see Chapter
an untraceable fault occurs repeatedly, please contact your service partner.
28/200 - en
Troubleshooting
"2 Using the charging station
Error 4003 [0011]
Overcurrent detected in the vehicle:
The vehicle has not adhered to the maximum permitted
current and has been switched off – should the prob-
lem persist, have the vehicle checked at a garage.
Error 8005 [0101]
Residual current detected in the vehicle:
Check the cable, possible damage due to a storm, tem-
porarily disconnect the charging station from the mains
and start the charging process again – should the prob-
lem persist, have the vehicle checked at a garage.
[23]") or possibly by restarting the charging station. If

Advertenties

loading

Deze handleiding is ook geschikt voor:

Kecontact p30