Download Inhoudsopgave Inhoud Print deze pagina

Self-Test; Operation; Charging The Rechargeable Battery; Trickle Charge - Mafell APS 10 M Vertaling Van De Originele Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 24

5.1 Self-test

Plug in the mains plug.
The warning display (4) and the operating mode
display (3) will light up in succession for approx.
1 second.
6

Operation

6.1 Charging the rechargeable battery

Push the rechargeable battery
pack(1) into the charging duct up to
the limit stop (2).
The operating mode display (3) is
blinking and the rechargeable
battery pack is charged.

6.2 Trickle charge

Once charging is complete, the
charger switches automatically to
trickle charge. The rechargeable
battery pack can remain inside the
charger and is thus always ready
for operation. The operating mode
display (3) lights up constantly.
8

Troubleshooting

Some of the most frequent defects and their causes are listed in the following chart. In case of other defects,
contact your dealer or the MAFELL customer service.
Defect
The warning display (4) lights up
constantly
The warning display (4) is blinking
Danger
Determining the causes for existing defects and eliminating these always
requires increased attention and caution. Pull the mains plug beforehand!
Cause
The rechargeable battery pack is
not charged, temperature too
high/too low
Rechargeable battery defective
The rechargeable battery pack
was not pushed properly into the
charging duct (2).
-13-
7

Service and maintenance

Danger
Pull the power plug during all
service work.
Always keep the appliance clean.
If the appliance fails despite diligent manufacturing
and test procedures, an authorised customer service
station for MAFELL electrical tools must carry out the
repair.
Store the appliance in a dry and frost-proof place.
If the supply cable is damaged, it must be replaced by
a MAFELL customer service station, because special
tools are required for this.
Danger
Only use MAFELL accessories and
spare parts. Have components, the
replacement of which has not been
described, replaced at a MAFELL
customer service station.
Elimination
If the rechargeable battery pack
temperature ranges between 0 °C
and 50 °C, the charging operation
starts automatically.
Immediately remove the
rechargeable battery pack from the
charger.
Push the rechargeable battery
pack in properly.

Advertenties

Inhoudsopgave
loading

Gerelateerde Producten voor Mafell APS 10 M

Inhoudsopgave