2. BEFORE USE
-
This appliance is packaged in a way as to protect it during transport. Take the appliance
out of its box and remove all packaging materials. You can keep the original box and other
packaging elements in a safe place. This will help you prevent product damage when
transporting it in the future. In case the original packaging is disposed of, make sure all
packaging materials are recycled accordingly.
-
Make sure all parts and components are included and in good conditions. If there is any
piece missing or in bad conditions, contact the Technical Support Service of Cecotec
immediately.
Box contents
-
ForceClima 7500 Soundless Connected portable air conditioner
-
Window kit.
-
Remote control
-
Instruction manual
3. PRODUCT INSTALLATION
NOTE:
-
Leave a minimum of 50 cm distance to walls and other objects. Fig. 6
-
Do not install and use the air conditioning in the bathroom or other humid environments.
-
Before using the portable air conditioner, keep it upright for at least two hours. When
moving it from one place to another, always do it with the device in an upright position and
leaving it in a flat surface.
-
The air outlet pipe should be 28-150 cm long, this length is based on the specifications of
the air conditioner. Do not use extendable pipes or replace the pipe with a different one,
this may cause the product to malfunction. The exhaust pipe must be clear of obstructions;
otherwise, it may cause overheating.
Installation of the air outlet pipe. Fig. 7
Stretch the air outlet pipe.
1.
2.
Insert the pipe into the air outlet.
3.
Turn the end counterclockwise to fix it to the air conditioner body.
NOTE:
-
The flat end of the exhaust pipe joints must be snapped into place.
-
The air outlet pipe shall not be twisted or bent more than 45°. Keep the outlet air vent free
of obstructions.
60
FORCECLIMA 7500 SOUNDLESS CONNECTED
Window sealing plate installation
The window sealing plate can be installed either vertically (fig. 8) or horizontally (fig. 9). Adjust
the size of the opening so that the sealing plate remains fixed in it.
-
The following checks must be applied to installations using flammable refrigerants:
-
The charge size is in accordance with the size of the room within which the refrigerant
containing parts are installed.
-
Ventilation machinery and outlets are properly operated and unobstructed.
-
If an indirect cooling circuit is used, the secondary circuit must be checked for the presence
of refrigerant.
-
Equipment marking remains visible and legible. Markings and symbols that are illegible
should be corrected.
-
The components or refrigerant piping are installed in a location where they are not
susceptible to exposure to any substance that may corrode the refrigerant containing
components, unless the components are constructed of materials that are inherently
corrosion resistant or are adequately protected against corrosion.
4. OPERATION
The following functions can be activated from the control panel or from the remote control.
On/Off
When the device is turned on, it will beep and enter standby mode. Touch the power key
to turn the device on and off.
Mode
Press the mode icon to switch between cooling, fan and dehumidification modes.
Night mode
Under the cooling mode, press the increase and decrease keys to activate the Sleep
mode. The device will operate saving energy and silently.
Increase and decrease
Use these keys to increase or decrease temperature and time.
Temperature cannot be increased or decreased in the fan or dehumidifying modes.
Fan speed/Wi-Fi
Under the cooling mode, press the key to select high or low wind speed operation.
This option is not available under the dehumidification mode.