UK
Storing
If there is a risk of frost, dismantle the appliance and accessories, clean them and store in
a place protected from frost.
The appliance can be put on the pool cover when the base plate is fitted or in the water
container when the base plate is taken off.
The appliance can be submerged under water up to the submerged operating depth men-
tioned in the technical data.
When using as submersible pump, Install the appliance so that the suction openings can-
not be blocked by foreign bodies (place the appliance on a firm, even base if necessary).
Ensure that the appliance is stable.
6.
Malfunctions and troubleshooting
Minor faults are often sufficient to cause a malfunction. In most cases, you will be able to
correct these faults easily yourself. Please start by referring to the following table before
contacting our technical support. This will help you save much effort and possibly expen-
se.
Fault/malfunction
Pump does not run.
Pump runs but does
not pump.
34
Cause
No mains voltage?
Motor overheats due to:
• liquid temperature too
high?
• blocking by foreign bodies?
Residual current circuit breaker
(RCCB) triggered?
Motor defective?
Suction openings blocked?
Pump draws in air?
Pump blocked by foreign bodies?
MV-1924-04-2022 . swim-fun.com © Alle rettigheder forbeholdes Swim & Fun A/S
Remedy
Check cables, plug, socket and fuse.
Eliminate the cause of the overheating
Activate RCCB.
Contact qualified electrician if RCCB
triggers again.
Contact service partner.
Keep the pump at an angle while submerging.
Switch the pump on and off several
times in order to expel air.
Clean the pump