1
Installation
Unscrew the cover element and
remove it from the device.
2
Power supply
Shut down the automatic circuit
breaker. Make sure that is shut
off in all poles.
3
Electrical connection
Connect the L wire to the L
terminal and the N wire to the N
terminal.
4
Preparing the device
Loosen the screws of the strain
relief clamp.
16
5
Cable routing
1. Slide in the cable through the
cable port.
2. Place the cable through the
strain relief clamp and tighten
the screws.
6
Wiring
Connect the L and N cable to the
terminal.
Mounting the device
7
Install the appliance to a suita-
ble ducting system as shown.
If necessary, use a connector