4.3
Secondary Suspension
Hanger
Where a hanger is provided, the bearing parts of the hanger shall be capable of
supporting ten (10) times the weight of the luminaire without permanent deformation
and shall be manufactured from non-combustible materials such as steel or its
equivalent.
Accessories
The design of the luminaire shall be such that removable accessories, e.g. colour frames
and barn doors, when properly inserted, cannot fall out of the luminaire.
Secondary Suspension
A secondary suspension shall be provided for the luminaire, except where the luminaire is
arranged for floor mounting or if it is intended for handheld use. The secondary
suspension shall be designed and mounted in such a way that in the event of a failure of
the primary suspension, no part of the luminaire can fall. The secondary suspension must
withstand a 30 cm vertical drop for 30 times.
4.4
Connection
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered
directly off a grounded switched circuit. Do not connect to a dimmer pack.
The installation has to be approved by an expert before the device is taken into
service.
5.
Operation
The device can be used in the following modes:
stand-alone mode
master/slave
with a DMX-512 controller.
5.1
Control Panel
Access the control panel functions using the four panel buttons located around the display.
Menu
scroll through the menu options
upwards through the menu list
downwards through the menu list
Enter
confirm a selection
Menu
Refer to the illustration on page 2 of this manual.
5.2
Stand-Alone Mode
The device starts running in stand-alone mode after connection to the mains. This mode allows you to
use the device without controller.
5.3
Master/Slave Mode
The master/slave mode allows for connecting several devices to a single master device in a daisy chain.
All slave devices will then work synchronously with the master device.
Configure all slave units before connecting the master unit to the daisy chain.
The maximum number of slave units you can connect to a master unit is 18.