8.7 Capacity Setting

1.
Simultaneously press the
conds
If
is displayed, press no further but-
tons (test mode manufacturer)!
Wait for approx. 10 seconds until the current time is
redisplayed!
2.
Enter the calculated set value via the
tons
3.
Press the
button three times to save the setting
9. Operation

9.1 Control Buttons, Display and Indicators

Service indicator
Display on:
Valve in service
Display flashing:
Regeneration on set time
(& Chapter 9.2.2)
Program indicator
Program mode entered
(Chapter 9.2)
Regeneration button
Brining and slow rinse

9.2 Display during Operation

During normal operation the time and residual capacity are displayed alternately
Time

9.3 Display during Regeneration

During regeneration the active regeneration phase is displayed. In addition to the phase number the remaining time of the active
regeneration phase is also displayed. After all 4 regeneration phases have been completed, the water conditioning device returns
to normal operation
Regnereration Phase 2, Remaining time 27 Minutes
9.4 "Bypass" function
9.4.1"Bypass" position
In this position the raw water is not softened
The raw water runs, via the bypass valve, through the connection adaptor back into the drinking water supply
"Service" position
9.4.2
In this position the raw water is softened and blended with hard water as to the setting of the blending adjuster
Start-Up operation
9.4.3
For the first 1-2 week running period the brand-new water conditioning device is in start-up operation
During this period noise development can occur during regeneration but will automatically disappear after approx. 1-2 weeks
MU1H-1412GE23 R1020
and
buttons for 5 se-
and
but-
Reverse rinse
Residual volume (litre)
GB
8.8 Manual Regeneration
Press the button
Manual regeneration starts immediately
Flushing takes place via the drain tube during regener-
ation!
The total time required for all 4 regeneration phases is:
approx. 52 min/PW50-AS
approx. 77 min/PW50-BS
approx. 102 min/PW50-CS
Rapid rinse
10
5 seconds
Flow indicator
Display flashing:
Water flow
Setting buttons
Set value
downwards
Set value
upwards
Brine refill
homecomfort.resideo.com