en Troubleshooting
Fault
The To-Go blade in-
sert cannot be con-
nected to the main
unit.
To-Go blender jug is
leaking.
Liquid is leaking from
the blade insert.
38
Cause and troubleshooting
Outlet protection is active.
Screw the To-Go blade insert and the To-Go
▶
blender jug in by turning them in a clockwise direc-
tion.
a The To-Go blender jug and To-Go blade insert are
fully and tightly screwed in.
Seal is missing from the lid.
Insert the seal.
▶
Seal between the blender jug and the blade insert is
missing.
Insert the seal on the EasyClick blade insert.
▶
a The seal is seated in the groove.
a The sealing lips point in the direction of the blender
jug.
a The smooth sealing surface lies against the EasyC-
lick blade insert.