Provide ample ventilation. This gas appliance consumes air (oxygen). Do not use this appliance in an unventilated space to
avoid endangering your life. If still more gas appliances and/or occupants using gas are added to the space, additional ventilation
Read these instructions carefully so as to familiarise yourself with the appliance before fiting the appliance to a gas cylinder.
1. General
• This appliance complies with BS EN498:2012 and SANS 1539:2012
• This appliance may only be used with an approved hose and regulator (A 2.8kPa hose and regulator supplied with this unit in South
Africa)
• The gas cylinder is to be used in the upright position.
• Only to be used with a gas cylinder that does not exceed 500mm in height(Regulator is included) and 400 mm in width.
• Gas appliances require ventilation for efficient performance and to ensure the safety of users and other persons in close proximity.
• Warning: Accessible parts may be very hot. Keep young children away.
• After use, turn off the gas supply at the cylinder, and then at the control knobs.
• Use outdoors only!
Country of Use
Appliance Catagories
Allowable gasses
Jet Number
Nominal Usage
Gross nom. heat input
Jet Number
Nominal Usage
Gross nom. heat input
Gas Supply Sources
AE = United Arab Emirates
CZ = Czech Republic
FR = France
JP = Japan
PT = Portugal
SK = Slovakia
For gas category I3B/P(30) & I3+(28-30/37)
Meridian 3 Built-in, 982231, total heat input: 9.6kW/Butane 699g/h
Meridian 4 Built-in, 982241, total heat input: 12.4kW/Butane 902g/h
For gas category I3B/P(37)
Meridian 3 Built-in, 982231, total heat input: 11.4kW/Butane 830g/h
Meridian 4 Built-in, 982241, total heat input: 15.2kW/Butane 1106g/h
503-0479 LEV5 - (982231, 982241) - Meridian BIB 2016-2017 (VanWard) User Manual 28mbar (EU+SA).indd 1
CAUTION
must be provided.
IMPORTANT
Retain these instructions for future reference.
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, LT, LU, LV, PT,
SK & SI
I
3B/P (30)
Butane @ 28-30mBar
Propane @ 28-30mBar
Butane/Propane mixtures
@ 28-30mBar
(South Africa 2.8kPa)
Main 3 Burner BBQ Unit
Butane - 233 g/h
per burner
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
Main 4 Burner BBQ Unit
Butane - 226 g/h
per burner
3.1 kW per burne
(3.1 kW x 4 = 12.4 kW in
total)
An approved hose and regulator connected to a refillable gas container not exceeding 9kg and
complying with local regulation in force
Country Name and Abbreviations
AL = Albania
AT = Austria
DE = Germany
DK = Denmark
GB = United Kingdom
GR = Greece
KR = Korea
NL = Netherlands
RO = Romania
RU = Russia
SE = Sweden
TR = Turkey
PL
I
3+(28-30/37)
Butane @ 28-30mBar
Propane @ 37mBar
0.92
Butane - 233 g/h
per burner
3.2 kW per burner
(3.2 kW x 3 = 9.6 kW in total)
0.92
Butane - 226 g/h
per burner
3.1 kW per burner
(3.1 kW x 4 = 12.4 kW in
total)
BE = Belgium
ES = Spain
HR = Croatia
NO = Norway
RS = Serbia
ZA = South Africa
1 1
GB
BE, CY, DK, EE, FR, FI, HU,
IT, LT, NL, NO, SE, SI, SK, RO,
HR, TR, BG, IS,LU, MT
& ZA
,
I
3B/P (37)
Butane @ 37mBar
Propane @ 37mBar
Butane/Propane mixtures
@ 37mBar
Butane - 276 g/h
per burner
3.8 kW per burner
(3.8 kW x 3 = 11.4 kW in total)
Butane - 276 g/h
per burner
3.8 kW per burner
(3.8 kW x 4 = 15.2 kW in total)
CH = Switzerland
FI = Finland
IT = Italy
PL = Poland
SI = Slovenia
19/12/2016 14:14:54