Manual Defrost
POLAR Back Bar Chillers feature an automatic
defrost. However, should the appliance require
an additional defrost period press and hold the
button for 3 seconds.
Press and hold the
stop defrosting.
Note: If a manual defrost is
started this resets the automatic
defrost timer. During defrost
periods the Defrost light is
illuminated.
Cleaning, Care &
Maintenance
Switch off and disconnect from the power
supply before cleaning.
Clean the interior of the appliance as often as
possible.
Do not use abrasive cleaning agents. These
can leave harmful residues.
Always wipe dry after cleaning.
A POLAR agent or qualified technician must
carry out repairs if required.
Troubleshooting
If your appliance develops a fault, please check the following table before making a call to the Helpline.
Fault
The appliance is not
working
The appliance turns on,
but the temperature is
too high/low
CB929-CB932_CC601_CC605_CD089_CE205-CE207_CF759_GH132-GH134_DP286-DP287_ML_A5_v19_20180410.indb 5
All manuals and user guides at all-guides.com

Cleaning the Condenser

Periodically cleaning the condenser can extend the
life of the appliance. The condenser is located at
the back of the appliance.
button for 3 seconds to
Replacing the Interior Lamp (for
CC601, CC605, CB929~CB932)
1. Turn Off and disconnect the appliance from the
2. Unplug the lamp from the socket.
3. Insert the new lamp into place.
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Condenser blocked with dust
Doors are not shut properly
Note: Use a soft brush or
vacuum cleaner to clean the fins
of the condenser, taking care
not to damage the fins.
WARNING: Allow the lamp to
cool before replacing. The lamp
remains hot immediately after
use.
mains power supply.
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Clean Condenser
Check doors are shut and seals are not
damaged