Sluit de externe randapparatuur welke de commando's genereert aan op COM-poort 2 en stel Com Port 2 in op CMD.
Af
Ag
Ah
Ai
Aj
Ak
Al
Am
Indeling 2 kg, g en lb
Grafity van de plaats waar het toestel
word gekeurd en geplaatst
Lineariteit aanpassing
Spanwaarde van het nulpunt, calibratie
gewicht van plaatsing 1,
calibratie gewicht van plaatsing 2,
Ad waarde van het nulpunt en
spangewichtswaarde, netto span Ad
waarde
gewichtseenheid
inschakelen / uitschakelen van
kg, g en lb
Filter waarde
Initial Nul range,
handmatig nulbereik,
auto zero-tracking snelheid
© Riba Weegtechniek B.V.
d1
= kg: - 0 = 1; 1 = 2; 2 = 5; 3 =
10; 4 = 20; 5 = 50
d2
= g: - 0 = 1; 1 = 2; 2 = 5; 3 =
10; 4 = 20; 5 =50
d3
= lb: - 0 = 1; 1 = 2; 2 = 5; 3 =
10; 4 = 20; 5 = 50
d1
= gravity factor of calibration
place. Data length = 8 including
decimal with leading
d2
= gravity of location of
operation place. Data length = 8
including decimal with leading
space (Hex code 20).
0
= Off;
d1
= ad value of zero point. Data
length = 8 including decimal with
leading space (Hex code 20). =
weight value
d2
= weight value of LD1. Data
length = 8 including decimal with
leading space (Hex code 20).
d3
= ad value of LD1. Data length
= 8 (integers only) with leading
space (Hex code 20).
d4
= weight value of LD2. Data
length = 8 including 69 decimal
with leading space (Hex code 20)
d5
= ad value of LD2. Data length
= 8 (integers only) with leading
space (Hex code 20). Aj ad value
of zero point (offset), span weight
value, net span AD value
as value
d1
= as value of zero point. Data
length = 8 (integers only) with
leading space (Hex code 20).
d2
= span weight value. Data
length =8 including decimal with
leading space (Hex code 20).
d3
= net span AD value. Data
length = Data length = 8 (integers
only) with leading space (Hex
code 20)
d1
= kg: - 0 = Off; 1 = On
d2
= g: - 0 = Off; 1 = On
d3
= lb: - 0 = Off; 1 = On
0
= level 1;
level 8;
d1
= initial zero range: - 0 = Off, 1
= 1%, 2 = 2%; ... 5 = 5%; 6 =
10%; 7 = 20%
45
1
= On
d1 =
1
= level 2; ... ;
7
=
8
= level 9