14.4 XT111C – 230V AC OR 115V AC
PTC / NTC
DI
PT100
9
10
11
12
8(3)A250V
8(3)A250V
3
5
1
2
4
6
7
8
N.O.
Alarm
Line
Sonde Pt100
Thermokoppel J, K, S
=9–11 (10);
115Vac voeding:
7-8
15. STANDAARD INSTELLINGEN
COD
Name
Set
Set point
Hy1
Differential
LS1
Minimum set point
US1
Maximum set point
S1C
Action type output
Ac
Anti-short cycle delay:
on
Minimum time a stage stays switched ON
ono
Minimum time between 2 following switching ON of
the same load
ALC
Alarm configuration
ALL
Minumum alarm (ALC=rE)
(ALC=Ab)
ALU
Maximum alarm (ALC=rE)
(ALC=Ab)
ALH
Alarm recovery differential
ALd
Alarm delay
dAO
Alarm delay at start up
So1
Output status with faulty pr.
tbA
1
Alarm relay disabling
AS
1
Alarm relay polarity
Lci
2
Start scale with current or voltage input
Uci
2
End scale with current or voltage input
OPb
Probe calibration
rES
Resolution
UdM
temp
Measurement unit
(
.)
current/voltage
(
PbC
Kind of probe
P3F
3
wire presence
rd
HES
Energy saving differential
i1F
Digital input configuration
i1P
Digital input polarity
did
Alarm delay for dig. input
Adr
Serial address
OnF
oFF function enabling
Ptb
Parameter table
rEL
Software release
Pr2
To access the Pr2
Enkel voor XT111C
1
Enkel voor toestellen met 4÷20mA of 0÷1V of 0÷10V
2
XT110-111C_V2.doc
Installing and Operating Instructions
Installing and Operating Instructions
9 10 11 12
Input 4÷20mA
0÷1V / 0÷10V
9 10 11 12
Hot-KEY
= 9(+) - 11(-)
Range
LS1÷US1
-Full Sc./ Full Sc.
Down Sc./ Set
Set/ Full Sc.
in= Inverse; dir=direct
0÷250 sec
0÷250 sec
0÷120 min
rE=relat.; Ab= absolute
0 ÷ |Start Sc.-Set|
Start Sc.÷ ALu
0 ÷ |Full Sc.-Set|.
ALL÷ Full Scale
0÷Full scale
0÷999 min
0÷23h 50min
oFF=open on=closed
no; yES
CL÷oP
-1999÷1999
-1999÷1999
-Full Sc./ Full Sc.
in=NO; dE=0,1; cE=0,01
°C=°C; °F= °F;
)
0=°C; 1=°F; 2=RH; 3=bar;
4=PSI, 5=off
Pt=Pt100; J=tcJ; c= tck;
S=tcS; Ptc=PTC; ntc= NTC;
0-1=0÷1V; 10= 0÷10V;
cur=0÷20mA
no=2 wires;
yES=3 wires
Down Sc./ Full Sc.
c-H / oFF / AuS / HES /
EAL / bAL
cL=closed; oP=open
0÷120m
0÷247
no=not enabled;
yES=enabled
Readable only
Readable only
Readable only
°C/°F
Lev
0/32
-
-1/-2
Pr1
min
Pr2
max
Pr2
in
Pr2
0
Pr2
0
Pr2
0
Pr2
rE
Pr2
10.0/ 20 Pr2
10.0/ 20 Pr2
2.0/4
Pr2
15
Pr2
1.3
Pr2
oFF
Pr2
yES
Pr2
oP
Pr2
various
Pr1
various
Pr1
0.0
Pr1
in
Pr2
various
Pr1
various
Pr1
no
Pr2
0.0
Pr2
EAL
Pr2
cL
Pr2
0
Pr2
1
Pr2
no
Pr2
--
Pr2
---
Pr2
321
Pr1
X T 1 1 0 C – X T 1 1 1 C
X T 1 1 0 C – X T 1 1 1 C
FRIGRO NV
DRIESLAAN 10
8560 MOORSELE
tel. +32 - 56419593 - fax +32 - 56403155
1592002210
3/3