1) Make sure all connections are correct and tight.
2) Make sure the port of drain valve is closed.
3) Make sure the MODE valve on RECOVERY position
4) Open the liquid port of the storage tank.
5) Open the output port of the unit and liquid port on the manifold
gauge set.
6) Turn the power switch to ON. Open the input valve slowly to liquid
position. Run until the recovery is achieved.
7) Turn the power switch to OFF. Open the port of oil drain valve,
and drain the oil into a suitable container, then close The oil
drain port.
8) Disconnect all hoses
All manuals and user guides at all-guides.com
OIL SEPARATING PROCEDURE
11 EN