Store the unit in a dry, cool place, free from moisture and direct exposure to sunlight.
•
The device must be regularly inspected to check its technical efficiency and spot any damage.
•
Do not use sharp and/or metal objects for cleaning (e.g. a wire brush or a metal spatula) because they
may damage the surface material of the appliance.
•
Do not clean the device with an acidic substance, agents of medical purposes, thinners, fuel, oils or
other chemical substances because it may damage the device.
Clean organic deposits from the device after every use with a stream of clean water and a soft cloth.
•
Disposing of Used Devices
Do not dispose of this device in municipal waste systems. Hand it over to an electric and electrical device
recycling and collection point. Check the symbol on the product, instruction manual and packaging. The plastics
used to construct the device can be recycled in accordance with their markings. By choosing to recycle you are
making a significant contribution to the protection of our environment. Contact local authorities for
information on your local recycling facility.
TROUBLESHOOTING
Problem
The device does not
start
The device starts but
does not pump / pumps
only a little water
EN
Possible reason
Overcurrent circuit breaker has
tripped
No power
Damaged engine or power cable
Water feed clogged
Leaking water connections
Insufficient water level in the
borewell
Water delivery head too height
Solution
Remedy the cause of the
circuit breaker tripping. Wait
for the motor to cool down.
Reset the circuit breaker to
its original position.
Make sure the power cable is
connected properly.
Call your agent or qualified
technician.
Remove the blockage.
Seal the connections.
Check the water level. The
pump should be at least 2 m
below the water surface.
Install the pump in
accordance with its technical
specification.