4.13 Switching off the hob

6.
Press the ON/Off key of the hob . The hob will be
switched off , irrespective of any settings.
Please note:
-
The hob will switch off automatically after 10 sec-
onds when all the cooking zones are switched of
manually (power setting 0) and no key/sensor
field is pressed afterwards.
-
The Power boost function is activated immediate-
ly.
See
the
-
Fan has an after run function
(see chapter 4.28 Fan after run)

4.14 Pause function

The cooking process can be briefly interrupted
with the Pause function, e.g. if the doorbell rings.
The Pause function must be released in order to
continue cooking at the same power level. If a
timer has been set it will pause and will then con-
tinue.
This function is only available for 10 minutes for
reasons of safety. The hob will then be switched off.
1. Pots and pans are on the cooking zones and the
required power levels have been set.
2. Press the Pause key "II". Instead of the selected
power settings, the interval sign "II" will light up
3. The interruption is ended by firstly pressing the
Pause key "II" and then pressing any other key
(except the ON/ OFF key).
Notes:
The pause symbol "II" also appears on the fan
display when the pause is active. The fan level (if
greater 0) is reduced to level 1.

4.15 Recall function

(recovery function)
The most recent setting can be recovered if the
hob is switched off unintentionally.
The recall function only works if at least one coo-
king zone is switched on.
1. The hob is inadvertently turned off by the ON/
OFF key of the hob.
2. Within 6 seconds after turning it off, press the
ON/OFF key of the hob again.
The Pause key blinks.
The Pause key must be pressed immediately af-
terwards.
The original cooking levels are restored. The
cooking process continues.
What can be restored:
-
Cooking levels of all cooking zones
-
Fan level
-
Minutes and seconds of programmed timer func-
tions
-
Automatic boost function
-
Power boost
Not to be restored:
-
Operation time limit (it is counted from 0)
section
on
Power
EN
setting.