The repairs or maintenance operations must only be carried out by qualified
personnel.
•
The unit must be checked by a qualified technician at least once a year.
•
Regularly check the conditions of gas hose, and gas regulator if it must be
replaced only use original spare parts.
•
Before starting any maintenance operation on the heater disconnect from both
gas and electrical suppliers.
•
If the unit has not been used for a long period we advise that a technician carries
out a general check up before using. It is important to control the following:
•
Periodically check the gas supply hose conditions and, should it be changed, use
only original spare parts.
•
Check the starting electrode position (see Fig.5).
•
Check the connections of the safety thermostat and of the thermocouple: they
must always be clean. If necessary clean the fan blade and the inside of the
heater using compressed air.
19. TROUBLESHOOTING
PROBEM
The motor does
not work
The motor works,
but
the
burner
does not light up
and
after
few
seconds the heater
stops
The burner lights
up but after few
Manual_FX-GH33_Int24_rev2
CAUSES
No electricity supply
The safety thermostat is on
The cylinder gas tap is closed
The cylinder is empty
The nozzle is obstructed
The solenoid gas valve is not open
There is no spark
No connection with the earthing
system
SOLUTIONS
Check the terminal board with a tester
Wait about one minute then restart
Open the gas tap
Use a new cylinder
Remove the nozzle and clean it.
Check that the solenoid valve works
Check the position of electrode
Check and connect properly
23