Connect the hose and regulator assembly to the LPG cylinder by rotating the nut
counterclockwise into the LPG cylinder's valve outlet and securely tighten.
Open the cylinder's gas valve and check all gas connections with a soap and
water solution.
Connect power cord to well-grounded 220-240V~, 50Hz source of power.
IGNITION / Manual ignition
Turn the power switch to position I and check that the fan starts running
correctly. (Figure. 2)
Figure.2
Push the gas valve button and push repeatedly the piezoelectric lighter until the
flame lights up. (Figure 3-4)
Figure.3
As the flame lights up, keep the valve button pushed for 10 seconds approx.
should the heater stop when the valve button has been released, wait one
minute and repeat the starting operation keeping the valve button pushed for a
longer time.
Regulate the gas flow pressure according to the thermal power desired, by
turning the wheel of the pressure reducer anticlockwise to increase the pressure
or clockwise to decrease.
Contact your supplier should any problem continue.
Regulate the flame and output by turning the adjustable knob anticlockwise to
increase or clockwise to decrease. (Figure 3).
CAUTION
If ignition is difficult or irregular before repeating the ignition operations make sure
that the fan is not locked and the air inlet and outlet are unobstructed.

16. SWITCH OFF

To stop the heater, shut off the gas cylinder tap. Let the fan run until the flame shuts
down and then turn the fan switch to position O.

17. AIR CONDITIONING

Manual_FX-GH33_Int24_rev2
Figure.4
21