Completely read through the operating instructions, the
"Warranty and Additional Information" booklet as well as
!
the latest information under the internet link at the end of
these instructions. Follow the instructions they contain.
This document must be kept in a safe place and passed on
together with the device.
Function/Application
Multimeter for taking measurements in the range of overvoltage
category CAT III up to max. 1000 V. The meter can be used to
measure DC and AC voltages and direct and alternating currents
within the specified ranges, as well as for continuity and diode
testing. The meter is also fitted with a non-contact voltage
detector and has an integrated LED flashlight.
Symbols
Fig. A: Hazardous electrical voltage warning: Unprotected live com-
ponents inside the device housing may pose a risk of electric shock.
Fig. B: Danger area warning
Fig. C: Protection class II: The test device has reinforced or double
insulation.
Fig. D: Overvoltage category III: Equipment in fixed installations and
for applications where specific requirements with regard to the
reliability and availability of equipment have to be met, e.g. circuit-
breakers in fixed installations and devices used in industrial applica-
tions which are permanently connected to the fixed installation.
Safety instructions
• The device must only be used in accordance with its intended
purpose and within the scope of the specifications.
• The measuring tools and accessories are not toys.
Keep out of reach of children.
• Modifications or changes to the device are not permitted, this will
otherwise invalidate the approval and safety specifications.
• Do not expose the device to mechanical stress, extreme
temperatures or significant vibration.
• Exercise extreme caution when working with voltages higher than
24 V/AC rms or 60 V/DC. Touching the electrical conductors at such
voltages poses a risk of life-threatening electric shocks.
• If the device comes into contact with moisture or other conductive-
residue, work must not be carried out under voltage. At and above
voltages of 24 V/AC rms / 60 V/DC, the presence of moisture
creates the risk of life-threatening electric shocks.
• Clean and dry the device before use.
MultiMeter-Pocket
11
EN