5.2.2
Switching the continuous measuring mode on and off
1. Press the Measure / Continuous measurement button for 2 seconds to activate continuous measure-
ment.
◁ The distance is shown in the display.
2. Press the Measure / Continuous measurement button again to end the continuous measurement.
5.2.3
Measuring area
1. Switch on the product. → page 10
2. Short-press the Area measurement / Units button.
3. Measure the length of the area by pressing the Measure / Continuous measurement button.
4. Measure the width of the area by pressing the Measure / Continuous measurement button.
◁ The area is calculated and the result is shown on the display.
5.2.4
Changing units
▶ Press the Area measurement / Units button for 2 seconds to toggle from one unit of measurement to
the other.
6
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
6.1

Fault codes

If a fault code appears, short-press the Measure / Continuous measurement button to return to the
measuring mode.
Restart the product if the fault code does not disappear automatically.
If a fault code re-appears, use the table below to find the corresponding information for dealing with the
problem.
Press the ON / Delete / OFF button to clear the fault code from the display.
Trouble or fault
204
240
252
253
254
255
256
257
258
260
7
Care, transport and storage
7.1
Care
▶ Keep the laser lens clear of dirt and finger marks.
▶ Clean the laser lens by blowing off dust or by wiping with a clean, soft cloth.
▶ Use only pure alcohol or water for cleaning.
2190182
*2190182*
Printed: 29.03.2018 | Doc-Nr: PUB / 5410137 / 000 / 00
4
8
Possible cause
Calculation error
Data-transfer fault
Temperature too high
Temperature too low
Battery voltage too low for mea-
surement
Incoming signal too weak
Measurement has taken too long
Incoming signal too strong
Too much background light
Measurement out of measuring
range
Laser beam interrupted
5
Action to be taken
▶ Take the measurement again.
▶ Repeat the procedure.
▶ Allow the product to cool down.
▶ Warm up to the product.
▶ Change the batteries.
→ page 10
▶ Use a different target surface
(e.g. white paper).
▶ Use a different target surface
(e.g. white paper).
▶ Use a different target surface
(e.g. white paper).
▶ Shade the target area.
▶ Correct the measuring range.
▶ Repeat measurement.
English