to a large extent. The water treatment through radiation also improves the health of the sh as
the level of germs in the water is reduced, decreasing the risk of infection. The physical principle
of radiation causes absolutely no change to the water values and has no negative e ect on the
cleansing bacteria in the lter, which are vital for the breakdown of pollutants.
The JBL PROCRISTAL Compact UV-C Water Clari ers can be safely operated to pressures of up to
0.5 bar. Therefore the operation with pumps which produce more than 0.5 bar pressure or the
direct connection to the water mains is not permitted.
Parts and descriptions
1
1 a
1 b
1 c
2
2 a
2 b
3
3 a
3 b
4
4 a
4 b
4 c
4 d
5
6
7
8
Installation
Important preliminary information:
Required for operation:
Commercially available pump for ponds or lter (pump) for aquariums with hose connection
facility.
10
All manuals and user guides at all-guides.com
Holder (lower part)
Holder (upper part)
Fixing screws for wall/ oor mounting
Screws for upper part
Electrical unit with electronic ballast, connection cable and plug
LED for operating check
O-ring for electrical unit
UVC bulb (5, 11, 18, 36 W)
Protective ring for bulb
Bulb cap
Quartz glass cylinder
Sealing collar
Union nut
Locking screw
Shock protection for quartz glass cylinder
Casing with integrated glass sleeve (5, 11, 18, 36 W)
Stepped hose tail 12/16/19 (models 5, 11, 18, 36 W)
Stepped hose tail 25/32/40 (models 18, 36 W)
Flat seal for stepped hose tail