outdoor unit:
indoor unit:
remote control:
This marking means that the AR-051 air conditioners have been designed for industrial
applications and comply with the requirements for Category 3 equipment used in potentially
hazardous areas due to the presence of gas, mist or vapor. This makes them suitable for use
in Zone 2.
The protection techniques used are Increased Safety (ec), Constructional Safety (h), Intrinsic
Safety (ic) and Molding (mc). Gas group IIB+H
ignition of gas, mist or vapor is T3 for the outdoor / condenser unit and T4 for the indoor /
evaporator unit. The AR-051 air conditioning system is suitable for ambient temperatures of
-27 °C up to +52 °C.
Type: AR-051/0311 C
II 3 G Ex ec h ic mc IIB+H
Cert. ARTIDOR 24ATEX9999 X
TF & Serial No.: AS241234
Artidor Explosion Safety B.V., Emopad 38, 5663 PB Geldrop
The Netherlands, +31 (0)40 7873911, https://artidor.com
Example of an outdoor unit label
Type: AR-051/0711
II 3 G Ex ec h ic IIB+H
Cert. ARTIDOR 24ATEX9999 X
TF & Serial No.: AS241234
Artidor Explosion Safety B.V., Emopad 38, 5663 PB Geldrop
The Netherlands, +31 (0)40 7873911, https://artidor.com
Example of an indoor unit label
Installation manual AR-051 explosion-safe air conditioning systems
II 3 G Ex ec h ic mc IIB+H
II 3 G Ex ec h ic IIB+H
2
II 3 G Ex ic IIC T6 Gc
T3 Gc
2
T4 Gc
2
T3 Gc
2
T4 Gc
applies. The temperature class for the
2
ARTIDOR
220–240 VAC 50 Hz
220 VAC 60 Hz
1.920 Watt
Year: 2024
ARTIDOR
220 – 240 VAC
50 Hz
40 Watt
Year: 2024
E
10-2024
7 / 44