All manuals and user guides at all-guides.com
WIND ALARM
Read high gust wind alarm and low wind chill alarm
PRESSURE
Toggle pressure unit among hPa, inHg and mb
CHANNEL/SEARCH Select indoor, Channel 1, 2, 3 or auto scroll
MEMORY
Read maximum/minimum records
HEAT INDEX/
Read heat index and dew point
DEW POINT
CLOCK
Read time, calendar and day of week
ALARM
Read alarm time; enable/disable alarm
▲ UP
1 Step forward in setting
▼ Down
1 Step backward in setting
SNOOZE/LIGHT
Trigger snooze alarm and extend backlight
WIND ALARM
Enable/disable high gust wind alarm and low wind chill alarm
Toggle wind speed unit among Beaufort, mph, m/s, km/h and
WIND UNIT
knot
RAIN UNIT
Toggle between mm and inch rainfall unit
Search for radio-controlled time
ZONE
Toggle RC time and zone time
°C/°F
Toggle degree unit between °C and °F
CONNECTING WITH REMOTE SENSORS
The weather station uses 433 MHz radio signals to send and receive weather data between the monitors and
remote sensors.
After battery/adapter installation, the monitor will automatically search for remote sensors.
You can also enforce a searching mode by holding "CHANNEL/SEARCH" on the monitor.
Follow the instructions in the "INSTALLATION" section to set up the sensors and wireless connection. If the
connection cannot be established, reset the remote sensor by removing the batteries from the sensor. Wait for
10 seconds and reinstall the batteries. Then hold "CHANNEL/SEARCH" on the monitor to search for the
sensors. If that continues to fail, shorten the distance between the sensor and monitor and reinstall the
sensors if necessary (for details, refer to the "INSTALLATION" section).
Anemometer (with built-in temperature and humidity sensor):
Important: Wind direction calibration is needed whenever the anemometer is reset (or during battery
replacement).
Searching mode display:
Wind direction, temperature and humidity information will flash.
RF Connection completed:
Valid wind speed/direction and Ch-1 temperature/humidity readings appear.
(It may take up to 10 minutes to receive all wind speed/direction and Ch-1 temperature/humidity readings
during the searching mode).
RF Connection failed:
"- - - -" wind speed appears; no wind direction. Unable to display Ch-1 temperature and humidity.
Rain Gauge:
Searching mode display:
Total rainfall information will flash.
RF connection completed:
Valid total rainfall reading appears.
RF connection failed:
"- - - -" stops flashing and stays on the total rainfall display (previous daily/weekly/monthly rainfall readings
remain on record).
Important: Select Ch-2 or 3 for additional remote thermo-hygrometer sensors since Ch-1 has been assigned
to the anemometer.
Searching mode display:
Temperature and humidity information will flash.
Press Functions
5
Hold 3 seconds
Enter high wind speed alarm and low
wind chill alarm setting
Sea level pressure setting
Search for all remote sensors
Clear memory record
Set clock and calendar
Alarm time setting
Fast advance
Fast backward
Zone time setting