Vorschriften
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Mechanical data
Actuating panels
Active area
Mechanical life, minimum
Note (Mechanical life)
Latching force, approx.
Mounting
Type of the fixing screws
Tightening torque of the fixing screws, minimum
Tightening torque of the fixing screws, maximum
Mechanical data - Switching distances according EN IEC 60947-5-3
Switch distance, typical
Assured switching distance "ON" S
Assured switching distance "OFF" S
Hysteresis (Switching distance), maximum
Repeat accuracy R
Note (Repeat accuracy R)
Mechanical data - Connection technique
Note (length of the sensor chain)
ao
ar
EN ISO 13849-1
EN IEC 61508
e
4
2,70 x 10⁻¹⁰ /h
2,10 x 10⁻⁵
3
20 Year(s)
zijdelingse
zijdelingse
1.000.000 Operations
Bedieningssnelheid 0,25 m/s
Schakelingen voor deuren ≤ 5 kg
18 N
Voor de montage van de sensoren en bij een zijdelingse
bevestiging van de bediensleutel volstaan schroeven met een
lengte van 25 mm. Als de bediensleutel aan de hoogkant
gemonteerd wordt en bij gebruik van sluitringen worden schroeven
met een lengte van 30 mm aanbevolen.
2x M4 (cylinder head screws with washers DIN 125A / form A)
2,2 Nm
2,5 Nm
12 mm
10 mm
20 mm
2 mm
0,5 mm
Zijdelingse afwijking: aan de lange zijkant bedraagt de maximale
hoogteafwijking (x) van sensor en bediensleutel 8 mm (bijv.
montagetolerantie of door het afzakken van de veiligheidsdeur). De
dwarsafwijking (y) bedraagt max. ± 18 mm (zie afbeelding:
werkingsprincipe).Minimumafstand tussen twee sensorsystemen
100 mm
Cable length and cross-section change the voltage drop dependiing
on the output current
6-25