Length of sensor
Width of sensor
Height of sensor

Ambient conditions

Degree of protection
Ambient temperature
Storage and transport temperature
Relative humidity, maximum
Note (Relative humidity)
Resistance to vibrations
Restistance to shock
Protection class
Permissible installation altitude above sea level, maximum

Ambient conditions - Insulation values

Rated insulation voltage U
i
Rated impulse withstand voltage U
Overvoltage category
Degree of pollution
Electrical data
Operating voltage
Operating current, minimum
No-load supply current I
, typical
0
Rated operating voltage
Operating current
Required rated short-circuit current
Time to readiness, maximum
Switching frequency, maximum
imp
Unlimited number of devices, oberserve external line fusing, max.
31 devices in case of serial diagnostic SD
Aansluitstekker M12, 8-polig
22 mm
106,3 mm
25 mm
IP65
IP67
IP69
-28 ... +70 °C
-28 ... +85 °C
93 %
niet-condenserend
geen berijping
10...55 Hz, amplitude 1 mm
30 g / 11 ms
III
2.000 m
32 VDC
0,8 kV
III
3
24 VDC -15 % / +10 %
0,5 mA
35 mA
24 VDC
600 mA
100 A
2.000 ms
1 Hz
7-25