Download Print deze pagina

dixell XT120C Installatie- En Bedieningsinstructies pagina 4

Tweetraps thermostaat met multiprobe ingang
Dixell
Dixell
Dixell
Dixell
15.5 XT120D – 230V AC OR 120V AC OR 24V AC
Analog
Out
8(3)A250V
8(3)A250V
LOAD 1
LOAD 2
Line
Probe: Pt100=11 - 10 (12); Thermocouple J, K, S= 11(+) -
10(-)
115Vac supply: 1-2; 24Vac supply: 1-2
15.6 XT121D – 230V AC OR 115V AC OR 24V AC
Analog
Out
8(3)A250V
8(3)A250V
LOAD 1
LOAD 2
Line
Probe: Pt100=11 - 10 (12); Thermocouple J, K, S= 11(+) -
10(-)
115Vac supply: 1-2; 24Vac supply: 1-2
XT120-121C-D_V2.doc
Installing and Operating Instructions
Installing and Operating Instructions
Installing and Operating Instructions
Installing and Operating Instructions
STANDAARD INSTELLINGEN
Input: 4÷20mA
COD
0÷1V / 0÷10V
Set1 Set point1
Set2 Set point2
10 11 12
Hy1 Differential 1
Hy2 Differential 1
PTC
NTC
LS1 Minimum set point1
LS2 Minimum set point2
US1 Maximum set point1
US2 Maximum set point1
ouC Output configuration
S1C Action type output 1
S2C Action type output 2
Ac
Anti-short cycle delay:
on
Minimum time a stage
stays switched ON
ono Minimum time between 2
following switching ON of
the same load
ALC Alarm configuration
ALL Minumum alarm (ALC=rE)
ALU Maximum alarm (ALC=rE)
ALH Alarm recovery differential 0÷Full scale
Input: 4÷20mA
ALd Alarm delay
0÷1V / 0÷10V
dAO Alarm delay at start up
So1 Out1 status with faulty pr. oFF=open on=closed
10 11 12
So2 Out2 status with faulty pr. oFF=open on=closed
tbA
1
Alarm relay disabling
PTC
NTC
AS
1
Alarm relay polarity
Lci
2
Start scale with current or
voltage input
Uci
2
End scale with current or
8(3)A250V
voltage input
OPb Probe calibration
rES Resolution
UdM Measurement unit (temp.)
Alarm
(current/voltage)
PbC Kind of probe
P3F 3
rd
wire presence
Aoc
3
Analog output
configuration
LAo
3
Lower An.Output limit
uAo
3
Upper An. Output limit
SAo
3
Analog output safety
HES Energy saving differential Down Sc./ Full Sc.
i1F
Digital input configuration c-H / oFF / AuS / HES
i1P
Digital input polarity
did
Alarm delay for dig. input 0÷120m
Adr Serial address
OnF oFF function enabling
Ptb
Parameter table
rEL
Software release
Pr2
To access the Pr2
1
Enkel voor XT111C/XT111D
2
Enkel voor toestellen met 4÷20mA of 0÷1V of 0÷10V
3
Enkel voor instrumenten met analoge uitgang
Name
Range
°C/°F Lev
LS1÷US1
0/32
LS2÷US2
1/34
-Full Sc./ Full Sc.
-1/-2 Pr1
-Full Sc./ Full Sc.
-1/-2 Pr1
Down Sc./ Set1
Down Sc./ Set2
Set1/ Full Sc.
Set2/ Full Sc.
ind= independent;
diP = dependent
in= Inverse; dir=direct
in= Inverse; dir=direct
0÷250 sec
0÷250 sec
0÷120 min
rE=relat.; Ab= absolute
0 ÷ |Start Sc.-Set1|
10.0/
(ALC=Ab)
Start Sc.÷ ALu
0 ÷ |Full Sc.-Set1|.
10.0/
(ALC=Ab)
ALL÷ Full Scale
2.0/4 Pr2
0÷999 min
0÷23h 50min
no; yES
CL÷oP
-1999÷1999
various Pr1
-1999÷1999
various Pr1
-Full Sc./ Full Sc.
in=NO; dE=0,1;
cE=0,01
°C=°C; °F= °F;
various Pr1
0=°C; 1=°F; 2=RH;
3=bar; 4=PSI, 5=off
Pt=Pt100; J=tcJ; c= tck;
various Pr1
S=tcS; Ptc=PTC; ntc=
NTC; 0-1=0÷1V; 10=
0÷10V; cur=0÷20mA
no=2 wires;
yES=3 wires
Pb = probe; Er =
Probe-Set1
Down Sc
various Pr2
Full sc.
various Pr2
on; oFF
/ EAL / bAL
cL=closing;
oP=opening
RS485 address
no=not enabled;
oFF=enabled
Readable only
Readable only
Readable only
XT120C
XT120C – – – – XT121C
XT120C
XT120C
XT121C
XT121C
XT121C
-
-
min
Pr2
min
Pr2
max Pr2
max Pr2
ind
Pr2
in
Pr2
in
Pr2
0
Pr2
0
Pr2
0
Pr2
rE
Pr2
Pr2
20
Pr2
20
15
Pr2
1.3
Pr2
oFF
Pr2
oFF
Pr2
yES
Pr2
oP
Pr2
0.0
Pr1
in
Pr2
no
Pr2
Pb
Pr2
oFF
Pr2
0.0
Pr2
EAL Pr2
cL
Pr2
0
Pr2
1
Pr2
no
Pr2
--
Pr2
---
Pr2
321
Pr1
1
1592002220
4/4