Tijdbasis ............................................................. 2,5 ms, 5 ms, 10 ms, 25 ms, 50
Verversingssnelheid ........................................... 0,5 seconden
Samplefrequentie ................................................ 15.625 kHz
Inschakelstroomfunctie
Bereiken .............................................................. 40, 400 en 2000 A
Resolutie ............................................................. 10 mA in 40A-bereik
Nauwkeurigheid
I > 10 A .......................................................... ± 5% uitlez. ± 1 pixel
I < 10 A ........................................................... ± 0,5 A
Alle metingen DC en 15 Hz tot 1 kHz
Maximale overbelasting ..................................... 10,000 A of RMS x frequentie
Stroom RMS is een True-RMS-meting (AC + DC)
Registratietijd ...................................................... 1, 3, 10, 30, 100 en 300 s
Samplefrequentie ................................................ 15.625 kHz
Digitale uitgang
USB-interface naar pc
Power Log-software voor downloaden, analyseren en rapporteren
345 upgradevoorziening voor het installeren van een nieuwe firmwareversie
Loggeheugen
Loggebieden ....................................................... Drie gebieden die afzonderlijk kunnen
Te middelen perioden ......................................... 1 s, 2 s, 5 s, 10 s, 30 s, 1 min., 5 min.,
Power Quality Clamp Meter
ms/div.
100 mA in 400A-bereik
1 A in 2000A-bereik
< 400,000.
worden gebruikt, of gecombineerd in
één groot gebied.
10 min., 15 min. en naar behoefte
Specificaties
9