FRONIUS PRIMO
Max. output fault current per period
General data
Maximum efficiency
European efficiency
Overnight self-consumption
Cooling
Degree of protection
Dimensions h x w x d
Weight
Permissible ambient temperature
Permitted humidity
EMC device class
Overvoltage category DC / AC
Inverter topology
Decisive Voltage Classification
(DVC-Rating)
Protection devices
DC insulation measurement
Response to DC overload
DC disconnector
Active Anti-Islanding Method
FRONIUS PRIMO
Input data
MPP voltage range
Max. input voltage
at 1,000 W/m²/ 14 °C in an open circuit
Max. input current (MPPT 1 / MPPT 2)
Max. short circuit current of the solar modules
4)
Max. feedback current
Output data
4.0-1
98.1 %
97.0 %
Controlled forced-air ventilation
AC
DC
Data
Warning/shutdown
Operating point shift, power limitation
5.0-1 AUS
240 - 800 V
4.6-1
38 A / 172 ms
98.1 %
97.0 %
0.6 W
IP 65
628 x 428 x 205 mm
21.6 kg
-40 °C - +55°C
0 - 100%
B
2 / 3
non-isolated transformerless
DVC-C
DVC-C
DVC-A
7)
at R
< 1 mOHM
ISO
Integrated
Frequency shift method
6.0-1
240 - 800 V
1000 V
18.0 A
27.0 A
27.0 A
5.0-1
98.1 %
97.1 %
8.2-1
270 - 800 V
53