Data transfer
This device has digital connectivity which allows wireless data transfer to
mobile devices such as smart phones or tablets with a wireless interface.
The system prerequisites for a digital connection are specified at
https://packd.li/ble/v2
This device can generate a wireless connection to devices which
are compatible with the wireless standard IEEE 802.15.4. The wireless
standard IEEE 802.15.4 is a transfer protocol for Wireless Personal Area
Networks (WPAN).
The range is set to a maximum distance of 10 m from the terminal
device and greatly depends on the ambient conditions such as the
thickness and composition of walls, sources of interference as well
as the transmit / receive properties of the terminal device.
Application (app)
An app is required to use the digital connection. You can download the
app from the corresponding stores for the specific type of terminal device:
!
Make sure that the wireless interface of the mobile device is
activated.
After starting the app and activating the digital connection, a connection
can be set up between a mobile device and the measuring device.
If the app detects several active measuring devices, select the matching
device.
This measuring device can be connected automatically the next time
it is switched on.
Error codes:
Er101:
Replace the battery
Er104:
Calculation error
Er155:
Outside the measuring range
Er157:
Received signal too weak
Er159:
Umgebungslicht ist zu stark
Er194:
Value outside display range
DistanceMaster Plus 100
19