Electrical connection
•
Before connecting the appliance to the power
supply, always follow the instructions and
warnings in the chapter entitled "Safety
instructions"!
•
The extractor hood may only be connected by a
qualified electrician who is familiar with the
regulations of the relevant electricity supply
company.
RISK OF INJURY
•
If the power cord of the extractor hood is
damaged, it must be replaced by the
manufacturer, his customer service or a
similarly qualified person to prevent hazardous
situations.
•
The extractor hood may be connected to a
correctly installed earthed socket only.
•
Attach the earthed socket as directly as
possible behind the flue duct.
–
The earthed socket should be connected via its
own circuit.
–
If the earthed socket is no longer accessible
following installation of the extractor hood, a
disconnector must be fitted as for a permanent
connection.
All manuals and user guides at all-guides.com
If a permanent connection is required
•
Electrical specifications
The required connection data can be found on the
rating plate inside the appliance when the grease
filters have been removed.
Length of the power cord: approx. 1.30 m.
This extractor hood complies with the EC
interference suppression regulations.
A disconnector must be provided on the
installation side. Switches with a contact
opening of more than 3 mm and all-pole
disconnection are regarded as disconnectors.
This includes LS switches, fuses and
contactors.
31