Download Print deze pagina

EINHELL TE-VC 36/30 Li S Originele Handleiding pagina 18

Accu nat-droogzuiger
Important!
Use only batteries which are charged to the same
level. Never combine full and half-full batteries.
Always charge the two batteries simultaneously.
The equipment's operating time depends on the
battery with the lower charge level. The two bat-
teries must always be fully charged before use.
Close the battery cover by swinging it down, and
make sure that it latches in place correctly.
Fitting the battery (Fig. 8)
Fold the battery cover (19) up as shown in Figu-
re 8. Then insert the two batteries (20) into the
mounts.
Battery capacity indicator (Fig. 12b/23)
Press the switch for the battery capacity indicator
(a). The battery capacity indicator (Fig. 23) shows
the charge status of the battery using 3 LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
6.1 On/Off switch (Fig. 1/2)
Switch position 0: Off
Switch position I: Vacuum setting 1
Switch position II: Vacuum setting 2
6.2 Dry vacuuming
Use the pleated fi lter (18) for dry vacuuming (see
point 5.2). The dirt bag (14) can be fi tted in additi-
on when removing particularly stubborn dirt (see
point 5.3).
Always ensure that the fi lters are securely seated!
Anl_TE-VC_36-30_Li_S_SPK13.indb 18
Anl_TE-VC_36-30_Li_S_SPK13.indb 18
GB
6.3 Wet vacuuming
For wet-vacuuming, use the foam fi lter (15) (see
point 5.2).
Check that the fi lter is securely seated at all
times!
Water drain screw (Fig. 1)
To make the tank (7) easier to empty after wet va-
cuuming, it is fi tted with a water drain screw (17).
Open the water drain screw (17) by turning it
counter-clockwise and drain the liquid.
When wet vacuuming, the fl oating safety switch
(Fig. 3/5) closes when the maximum tank level
is reached. In doing so, the suction noise of the
equipment will change and become louder.
You must then switch off the equipment and em-
pty the tank.
Danger!
The wet and dry vacuum cleaner is not suitable
for the vacuuming of combustible liquids.
For wet vacuuming, use only the supplied foam
fi lter.
6.4 Blowing
Connect the suction hose (10) to the blow con-
nector (9) on the wet and dry vacuum cleaner.
6.5 Cleaning the appliance head (1/3)
Clean the appliance regularly with a damp cloth
and some soft soap. Do not use cleaning agents
or solvents; these may be aggressive to the plas-
tic parts in the appliance.
6.6 Cleaning the container (1/7)
The container can be cleaned with a damp cloth
and some soft soap or under running water, de-
pending on the amount of dirt.
6.7 Cleaning the fi lters
Cleaning the pleated fi lter (Fig. 2a)
Clean the pleated fi lter (18) regularly by carefully
patting it and cleaning it with a fi ne brush or hand
brush.
Cleaning the foam fi lter (2a)
Clean the foam fi lter (15) with a little soft soap un-
der running water and allow it to air-dry.