Download Print deze pagina

VEVOR NAP002 Gebruikershandleiding pagina 9

Luchtgestuurde hydraulische voetpomp
MAINTENANCE
1. Inspect the connections
Please Inspect hoses and connections and tighten connections as needed.
Use a non-hardening pipe thread compound when servicing connections.
2. Adding Hydraulic Fluid
●Depressurize and disconnect the hydraulic hose from the application.
●With the pump in its upright, horizontal position, remove the oil filler plug
located on the top plate of the reservoir.
●Use a smallfunnel to fill reservoir to within 3/4"( 19mm)of the opening.
●Wipe up any spilled fluid and reinstall the oil filler plug.
Note: Use only or other approved hydraulic oil. Never use brake fluid,
transmission fluid, turbine oil, motor oil, alcohol, glycerin, etc. Use of other
than good quality hydraulic oil will void the warranty and damage the pump,
hose, and application.
3. Changing Hydraulic Fluid
●For best results, change the fluid once a year.
●Repeat step 2 above, and then pour the used fluid into a sealable
container.·Dispose of the fluid in accordance with local regulations.
●Fill with good-quality hydraulic oil as recommended above. Reinstall the
vented oil filler plug.
4. Lubrication
Use a light machine oil to lubricate pivot points, hinges, etc.
5. Storage
● Depressurize and disconnect hydraulic hoses from the application.
●Clean the pump and hose, and couplers.
●Store in a clean, dry environment; avoid temperature extremes.
- 8 -