You can select the following settings:
IDS OFF: The Intelligent Dosing System is deactivated.
IDS 1: Recommended for indoor pools and small outdoor pools
IDS 2: Recommended for pools up to 65 m³ with a dosing pump performance of 2,4 l/h
IDS 3: Recommended for pools >65 m³ with a dosing pump performance of 2,4 l/h
3.6 Switch-on delay
Corresponds to the start delay of the control unit in minutes. Every time the system is
started, the dosing is locked until the delay has been processed.
Rule of thumb: Delay in minutes = backwash time + 2 min
The set switch-on delay is displayed along with the minimum and maximum setting
values.
3.7 Limit pH
The dosing time limit prevents a dangerous incorrect dosage if the electrode fails. The
value must be adjusted in line with the pool size. For example: In the event of an
accident, with a set dosing time limit of 60 minutes, a maximum of 2,4 litres of water
care product can be dosed (pump performance 2,4 l/h). After this, the system switches
itself off. Limit appears in the display, the triggered alarm can be acknowledged by
pressing the OK button.
The dosing time as well as the minimum and maximum setting values are displayed.
3.8 Limit disinfection
Description of the dosing time limit for disinfection, see section 3.7*
(not for active oxygen)
4
pH settings
4.1 Calibration of the pH probe
Since pH measuring probes are subject to a certain level of variance, they must be
calibrated for every measuring and control device. Prior to initial operation, the
protective cap must be removed from the probe. The probe must be free of
contamination, oils and greases. The diaphragm (small point on the tip of the probe)
must also be free from deposits, contamination and crystallisations. For this reason, the
glass body should not come into contact with your hands.
(See also: Part II: Safety, installation and regular maintenance)
Caution:
Make
sure
that
the
plug
and
cable
are
kept
completely
dry.
Note: Do not get the connections confused.
38