REMOVING THE INSULATION

The insulation can be removed to facilitate handling in
confined spaces.
(Diameter without insulation is for VPB 500 Ø668 mm,
for VPB 750 Ø766 and for VPB 1000 Ø866 mm).
• Lift off the plastic top and the top insulation.
• On VPB 500, the lifting eye on the top must be un-
screwed first.
• Remove the joining plates holding the insulated jacket
halves together. Do not use any tools when dismant-
ling.
• Unhook and remove the insulated jacket halves.
The figure shows VPB 1000
with insulation.
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion. Finally, fit all the enclosed cover discs on each
connection by pressing them over the connections.
In certain cases, more insulation plugs are enclosed than
are required.
Caution
Fit the cover discs and the insulation plugs
before installing the pipe.
20
Do not use any tools when
dismantling the joining plate
Insulation removed.