Recommended cleaning method
1. Loosen dirt: Spray the detergent sparingly and let it
take effect for 1... 5 minutes, but do not let it dry.
2. Remove dirt: Rinse off the loosened dirt with the
high-pressure jet.
Cold water operation
For removing light contamination and for rinsing,
e.g. garden machines, terrace, tools.
1. Adjust the working pressure as required.
Eco level
The device works in the most economical temperature
range (max. 60 °C).
Operation with hot water
DANGER
Hot water
Risk of scalding
Avoid contact with hot water.
1. Set the power switch to the desired temperature.
Recommended cleaning temperatures
● 30-50 °C: Light soiling
● Max. 60 °C: Soiling containing protein, e.g. in the
food industry
● 60-90 °C: Car cleaning, machine cleaning
Interrupting operation
1. Lock the high-pressure gun by pushing the safety
latch forwards.
After operation with detergent
1. Set the detergent dosing valve to "0".
2. Set the power switch to level 1 (operation with cold
water).
3. Flush the device clean for at least 1 minute with the
high-pressure gun open.
Switching off the device
DANGER
Hot water hazard
Risk of scalding
After operation with hot water, the device must be oper-
ated with an opened gun with cold water for at least 2
minutes.
1. Close the water inlet.
2. Open the high-pressure gun.
3. Switch on the pump with the power switch and let it
run for 5-10 seconds.
4. Close the high-pressure gun.
5. Set the trigger to "0/OFF".
6. Only pull the mains plug out of the socket only when
your hands are dry.
7. Remove the water connection.
8. Actuate the high-pressure gun until the device is
completely depressurised.
9. Lock the high-pressure gun by pushing the safety
latch forwards.
Storing the device
Note
Do not kink the high-pressure hose or the electrical line.
1. Snap the spray lance into the holder on the device
cover.
2. Roll up the high-pressure hose and the electrical
line and hang them on the supports.
20
ATTENTION
Frost hazard
Destruction of the device through freezing water
Store the device that has not been completely drained
of water in a frost-free place.
In the case of devices that are connected to a chimney,
the ingress of cold air must be taken into account.
ATTENTION
Cold air entering through the chimney
Risk of damage
When the exterior temperatures are below 0 °C, discon-
nect the device from the chimney.
1. Shut down the device if frost-free storage is not pos-
sible.
For longer breaks in operation or when frost-free stor-
age is not possible:
1. Drain the detergent tank.
2. Drain the water.
3. Flush the device with antifreeze.
1. Unscrew the water supply hose and the high-pres-
sure hose.
2. Unscrew the supply line at the boiler base and allow
the heating coil to drain.
3. Allow the device for run for a maximum of 1 minute
until the pump and lines are empty.
Flushing device with antifreeze
Note
Observe the handling instructions of the anti-freeze
manufacturer.
1. Pour a commercially available antifreeze into the
float tank.
2. Switch on the device (without burner) and allow it to
run until the device is completely flushed.
This also provides a certain degree of corrosion protec-
tion.
ATTENTION
Improper transport with a factory truck
Risk of damage
Pay attention to the orientation of the device when
transporting it with a factory truck.
Illustration L
ATTENTION
Improper transportation
Risk of damage
Protect the trigger of the high-pressure gun from damage.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during transporta-
tion.
1. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respectively applicable guidelines.
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
English
Frost protection
Shutting down
Draining the water
Transport
Storage