Notices about unit operation
1.
When moving the unit, do not tilt over 45°to avoid any damaging of the compressor.
2.
The unit should be operated between 5°~32°.
3.
When dehumidifying, because of the heat resulted from the running compressor, the
indoor temperature will rise by 1°~3°. Such a reaction should be considered as normal.
4.
When indoor temperature is below 10°, and the ambient absolute humidity is quite low, it
is unnecessary to use the machine.
5.
Air inlet and air outlet should be at least 10cm away from the wall.
6.
Try to keep the room closed to enhance the dehumidi¿ cation effect.
7.
Too much dirt on the ¿ lter affects dehumidi¿ cation, may even result in malfunctioning of
it, thus it should be cleaned at least once a month. If there is a great amount of powder in
the air, the ¿ lter must be cleaned once a week, or even every day. Pull the front panel out
and clean the ¿ lter. If necessary, you may slightly knock all over the ¿ lter, use a vacuum
cleaner to remove bigger pieces of dirt or even wash the ¿ lter in warm clean water
(40% with some neutral detergents) and then dry it.
Trouble-shooting
Malfunction
Analysis
Unit does not
1.Power cut
work
2.Switch off
3.Unplugged
4.Fuse melted
5.Tank full
Dehumidi¿ es
1.Filter choked by dirt
in inadequately
2.Some barrier
in air inlet or outlet
3.Door or windows open
4.Refrigerant leakage
Water leakage
1.The unit is inclined
2.Drainer choked
Strange noise
1. Until instable
2. Filter choked
1.
When above malfunctions occur and they could not be removed, please contact the
supplier or seller, do not disassemble the machine yourself.
2.
When the unit starts or stops running, it makes certain noises of refrigerating circulation,
GB_DH_751.indd 9
All manuals and user guides at all-guides.com
INFORMATION
9
Solution
1.Power on
2.Switch on
3.Plug on
4.Exchange fuse
5.Empty the tank and replace it
1.Clean the ¿ lter
2.Remove the barrier
3.Close the door and windows and
seclude from the sunshine
4.Contact the manufacturer or seller
1.Adjust the unit to be stable
2.Pull out the panel and remove the
barrier
1.Place the unit stably
2.Clean the ¿ lter
2007-04-05 14:47:39