9
Technical data
INPUT (DC)
Max. recommended PV
3100 W
power
Nominal power
2750 W
Voltage range
125 ... 540 V
MPP range
150 ... 450 V
Full power MPP range
150 ... 450 V
Nominal current
10.0 A
Max. current
18.0 A
Stand-by power
< 0.2 W
STANDARDS / DIRECTIVES
Protection degree
IP65
Safety class
1
Configurable trip
Yes
parameters
Insulation monitoring
Yes
Current limitation;
Overload behavior
power limitation
EN60950-1; EN50178;
Safety
IEC62103; IEC62109-1 / -2
DIN VDE 0126-1-1; RD 1663;
Anti-islanding
RD 661; ENEL G.L. 2010; UTE
protection
15712-1; Synergrid C10/11;
EN 50438; G83/1-1
EN61000-6-2; EN61000-6-3;
EMC
EN61000-3-2; EN61000-3-3
GENERAL SPECIFICATION
Model name
SOLIVIA 2.5 EU G3
Max. efficiency
96.0 %
Efficiency EU
94.4 %
Operating temperature -25 ... +70 °C
Storage temperature
-25 ... +80 °C
Humidity
0 ... 98 %
30
All manuals and user guides at all-guides.com
P
* The maximum AC power value indicates the power
** AC voltage and frequency range will be programmed
Operation and installation manual SOLIVIA 2.5 EU G3
OUTPUT (AC)
Max. power *
2600 W
Nominal power
2500 W
Voltage range **
184 ... 264 V
Nominal current
11.0 A
Max. current
13.0 A
Nominal frequency
50 Hz
Frequency range **
47.0 ... 52.0 Hz
Power factor
> 0.99 @ nominal power
Total harmonic
< 3 % @ nominal power
distortion (THD)
MECHANICAL DESIGN
Size (L x W x D)
410 x 410 x 180 mm
Weight
21.5 kg
Cooling
Convection
AC connector
Wieland RST25i3S
DC connector pairs
3 Tyco Solarlok
Communication
2 Harting RJ45 / RS485
interfaces
DC disconnector
Integrated
Display
LCD; 3 LEDs
an inverter might be able to deliver. However, such a
maximum AC power may not necessarily be achieved.
according to the individual country requirements.