Download Inhoudsopgave Inhoud Print deze pagina

Control Panel Fault Messages - Dometic COOLAIR SPX1200I Gebruiksaanwijzing

Stand
Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 135
RTX1000/2000, SPX1200
8.2

Control panel fault messages

The "ERROR" symbol (fig. 4 5, page 5) lights up if there is a fault with the parking
cooler. The type of error is shown on the display by the following error codes:
Display
Description
text
F01
The compressor does not
work.
F02
F03
F04
The condensor fan 1 does
not work.
F05
The condensor fan 1 is
overloaded.
F06
The condensor fan 2 does
not work.
F07
The condensor fan 2 is
overloaded.
F08
The evaporator fan does
not work.
F09
The evaporator fan is
overloaded.
F10
The condensation water
that has formed is not
being discharged.
F11
The system cannot
determine the internal
temperature.
F12
EN
Cause
Error in compressor sensor
electrical supply (open
circuit).
Error in compressor sensor
electrical supply (short
circuit).
Compressor overload
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
The condensation water
that has formed is not being
discharged.
Error in temperature sensor
electrical supply (open
circuit).
Error in temperature sensor
electrical supply (short
circuit).
Display messages
Remedy
➤ Switch off the system.
➤ Switch it on again after
30 minutes.
➤ If the fault occurs again,
contact an authorised
workshop.
21

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Coolair rtx2000Coolair spx1200tCoolair rtx1000

Inhoudsopgave