Proceed as described above to delete all indi-
vidually set starting times, until the display
shows
. Briefly depress the cancel
Select day +/-
button C (r).
After this, the programme pre-set by the facto-
ry reappears (for all days: 1
heating operation 06:00 hrs; 1
for economic operation 22:00 hrs, further
starting times
).
--:--
When no more alterations are necessary
close the lid.
6.2.5 Control knob set to
"Holiday"
Setting the period of absence
Turn the control knobr (n) to
(e) shows:
Days absent +/-
0
4217-23.1/G
The number of days absent is set by depress-
ing the buttons "–" (o) or "+" (p).
Briefly depressing the button alters the
number of days absent by 1 day, when the
button is depressed for a longer period the
displayed days run faster.
Note:
The present day must be entered as
a day absent, i.e. the regulator
starts with the holiday programme
immediately. The day of return
should only be entered if no heating
operation is required for that day!
Example: You would like to leave your house
for a two weeks' holiday. You leave the house
Saturday afternoon. Return is planned for Sat-
urday, two weeks later, and you would like the
house to be heated by then.
If you enter the number of days absent shortly
before leaving, the number entered must be
"14" (Saturday, Sunday, ... Thursday and Fri-
day, since on the Saturday you return you
want the regulator to switch the heating sys-
tem on as usual.
24
All manuals and user guides at all-guides.com
st
starting time for
st
starting time
. The display
After closing the lid, the display (e) shows:
14 days absent
17:53 16.5°C
4217-24.1/G
The regulator immediately regulates to the
temperature set with the control knob
The remaining days until you return are al-
ways displayed. After the set number of days
(at midnight) the regulator automatically termi-
nates economic operation and returns to auto-
matic operation.
If you would like to carry out further alterations
do not yet close the lid.
Please note that the temperature set
Tip
with the control knob
less to your pets, plants, etc. for the entire
course of your absence.
If you intend to return to your house in the
morning, it might be better to start heating
shortly after midnight instead of waiting for
first heating operation in the morning. In this
case, depress the button
set the number of days absent. The display
shows:
. Now you can set the oper-
Automatic +/-
ating mode required on return with the button
"+" (p) or "–" (o), either to continuous heating
operation or to automatic operating mode. If
you have selected continuous heating opera-
tion, the temperature is regulated to the value
set with the control knob
midnight before your return. Do not forget to
depress the button
order to terminate continuous heating opera-
tion.
In case that the holiday operating mode
should be terminated early, it is possible to
either briefly depress the button
or to set the number of days absent to "0" as
described above.
Continuous heating operation for several days
can also be programmed by setting the
number of days as described above and turn-
ing up the economic temperature to the re-
quired value with the control knob
TR 200
(m)
(m) should be harm-
(q). after having
(k), beginning at
(g) after your return in
(g) twice,
(m).