Target group for this instruction manual

I
NOTE
• Please ask your vehicle manufacturer if a technical inspection is
required after fitting an air conditioner and whether the height entered
in the vehicle documents needs to be altered (increased height
210 mm).
2.2

Handling electrical cables

!
WARNING!
• The electrical power supply may only be connected by a qualified
electrician (e.g. VDE 0100, Part 721 in Germany).
!
CAUTION!
• Fit a fuse of at least 10 amps to the connection with the vehicle's power
supply.
• Attach and lay the cables so that they cannot be tripped over or
damaged.
A
NOTICE!
• Use cable ducts to lay cables through walls with sharp edges.
• Do not lay loose or bent cables next to electrically conductive
materials (metal).
• Do not pull on the cables.
3
Target group for this instruction manual
The instructions in this manual are intended for qualified personnel at workshops
who are familiar with the guidelines and safety precautions to be applied.