Installation

3.
Installation
3.1

Safety instructions for installation

D WARNING!
Hazard through disregard of the installation instructions!
This chapter contains important information for the safe
installation of the device.
☞ Read through this chapter carefully before installing the
device.
☞ Follow the safety instructions.
☞ Carry out the installation as described.
y Installation only by qualified specialist personnel.
D "1.2 Authorised target groups" (page 92).
y Electrical work only to be undertaken by qualified
electricians.
D "1.2 Authorised target groups" (page 92).
y Installation requires two persons.
y When working at heights, ensure good stable footing
(e.g. stable stepladder).
y The hob and other parts that can be touched must be
allowed to cool prior to installation.
y Store the film or other parts of the packaging in a location
which is inaccessible to children.
y The device must be in an undamaged and fault-free
condition prior to installation.
y Cables must not be kinked, crushed or damaged.
y Never open the fan housing.
y The power supply voltage must match the voltage
information quoted on the ratings plate.
D "2.5 Technical data" (page 94).
y Ensure that the power supply is stable and remains so
prior to the installation.
Connect the power supply only when instructed to do so
in the installation instructions.
6003417_a – 26.09.2017
All manuals and user guides at all-guides.com
3.2
Risk of death due to improper installation!
Disregard of the ambient conditions can lead to hazardous
situations, e.g. in the handling of electrical power or gas.
☞ Make sure that the requirements for the installation
y Do not install in potentially explosive atmospheres.
y With simultaneous use of a heating point which uses air
y Installation is only permitted on structural building
y If installed above fireplaces that use solid fuels (e.g. coal
y The air flowing out must be able to dissipate unimpeded.
y Make sure that the building electrical supply is properly
y The power supply voltage present must match the
y There must be an electrical power outlet in the vicinity of
y The mains plug must be accessible after the installation of
 Country-specific, legal provisions must be observed.
3.3
y Filter filling freely accessible for changing.

Requirements for the installation location

D WARNING!
location are complied with.
from the room as its oxygen supply (e.g. chimneys):
y A safety device is absolutely essential.
y The safety device (e.g. under-pressure monitor P4,
inspected in accordance with DIN 18841:2005-12 TÜV
and in accordance with DVGW-VP121) must prevent
gases being drawing to the room.
y An approval for commissioning (e.g. from a
chimneysweep) must be available.
elements capable of bearing the load (solid structure).
stove):
The fireplace must have a sealed cover which cannot be
removed. Otherwise there is a fire risk due to flying sparks.
Applicable legal and country-specific regulations must be
observed.
Do not impede the air flow, e.g. through the installation of
objects on or above the device.
earthed.
voltage information quoted on the ratings plate.
the device installation.
the hood.

Requirements for recirculated air mode