Download Print deze pagina

Hilti TE 500-A36 Originele Handleiding pagina 25

Generatie 04
Verberg thumbnails Zie ook voor TE 500-A36:

Advertenties

Battery state of charge cannot be displayed while the control switch is pressed and for up to 5
seconds after releasing the control switch.
If the battery display LEDs blink, please observe the instructions given in the Troubleshooting
section.
Items supplied
Breaker, side handle, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or
at: www.hilti.group
Technical data
Product generation
Rated voltage
Weight in accordance with EPTA procedure 01
Single impact energy in accordance with EPTA procedure 05
Chuck
Storage temperature
Ambient temperature for operation
Noise information and vibration values
The sound pressure and vibration values given in these instructions were measured in accordance
with a standardized test and can be used to compare one power tool with another. They can also be
used for a preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used
for different applications, with different accessory tools, or is poorly maintained, the data can vary.
This can significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the power tool is
switched off, or when it is running but not actually being used for a job. This can significantly reduce
exposure over the total working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration,
for example: maintaining the power tool and accessory tools, keeping the hands warm, organization
of work patterns.
Detailed information on the versions of the EN 62841 standards applied here is to be found in
the reproduction of the declaration of conformity
Noise emission values in accordance with EN 62841
Sound pressure level (LpA)
Uncertainty for the sound pressure level (KpA)
Sound power level (LWA)
Uncertainty for the sound power level (KWA)
Total vibration in accordance with EN 62841
Uncertainty (K)
*2240495*
2240495
TE 500-A36
04
36 V
7.9 kg
7.8 J
TE­Y
−20 ℃ ... 70 ℃
−17 ℃ ... 60 ℃
268.
TE 500-A36
94 dB
3 dB
102 dB
3 dB
TE 500-A36
1.5 m/s²
20