Trouble or fault
The power tool or battery
gets very hot.
No response from the LEDs
on the battery.
1 LED on the battery flash-
es.
4 LEDs on the battery flash. Product momentarily overload-
Product does not develop
full power.
The insert tool cannot be
released from the chuck.
Product does not start.
Service indicator shows.
Service indicator flashes.
The ON/OFF indicator flash-
es.
Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled.
The materials must be correctly separated before they can be recycled. In many countries, your old
tools, machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti
representative for further information.
25
Possible cause
The product is overloaded (appli-
cation limit exceeded).
The battery is not fully inserted.
Battery is discharged.
The battery is too hot or too
cold.
Battery is discharged.
The battery is too hot or too
cold.
ed.
Protection against overheating.
The control switch is not fully
pressed.
The half-power button is en-
gaged.
The chuck is not pulled back
fully.
The side handle is not fitted cor-
rectly.
The electronic restart interlock is
activated after an interruption in
the electric supply.
Service limit time reached.
The product is faulty.
Product momentarily overload-
ed.
Protection against overheating.
Action to be taken
Select a product that is
suitable for the intended
purpose.
Push the battery in until it
engages with a double click.
Change the battery and charge
the empty battery.
Bring the battery to the recom-
mended working temperature.
Change the battery and charge
the empty battery.
Bring the battery to the recom-
mended working temperature.
Release the control switch
and then press it again.
Allow the product to cool
down and clean the air vents.
Press the control switch as far
as it will go.
Press the "half-power" button.
Pull the chuck back as far
as it will go and remove the
accessory tool.
Disengage the side handle
and refit it correctly so that
the clamping band and side
handle engage in the recess.
Switch the product off and
then on again.
Have the product repaired by
Hilti Service.
Have the product repaired by
Hilti Service.
Release the control switch
and then press it again.
Allow the product to cool
down and clean the air vents.
2240495